dc.contributor.author |
Yalman, Yunus |
|
dc.contributor.author |
Celik, Ozgur |
|
dc.contributor.author |
Tan, Adnan |
|
dc.contributor.author |
Bayindir, Kamil Cagatay |
|
dc.contributor.author |
Cetinkaya, Umit |
|
dc.contributor.author |
Yesil, Merden |
|
dc.contributor.author |
Akdeniz, Mevlut |
|
dc.contributor.author |
Tinajero, Gibran David Agundis |
|
dc.contributor.author |
Chaudhary, Sanjay K. |
|
dc.contributor.author |
Guerrero, Josep M. |
|
dc.date.accessioned |
2022-12-22T06:26:56Z |
|
dc.date.available |
2022-12-22T06:26:56Z |
|
dc.date.issued |
2022-08 |
|
dc.identifier.citation |
Yalman, Y., Celik, O., Tan, A., Bayindir, K. C., Cetinkaya, U., Yesil, M., Akdeniz, M., Tinajero, G. D. A., Chaudhary, S. K., Guerrero, J. M., & Khan, B. (2022). Impacts of Large-Scale Offshore Wind Power Plants Integration on Turkish Power System. IEEE Access, 10, 83265-83280. https://doi.org/10.1109/ACCESS.2022.3196779 |
tr_TR |
dc.identifier.issn |
2169-3536 |
|
dc.identifier.uri |
http://openacccess.atu.edu.tr:8080/xmlui/handle/123456789/4052 |
|
dc.identifier.uri |
http://dx.doi.org/10.1109/ACCESS.2022.3196779 |
|
dc.description |
WOS indeksli yayınlar koleksiyonu. / WOS indexed publications collection. |
tr_TR |
dc.description.abstract |
In this paper, the impacts of large-scale OWPPs penetration on the Turkish power system are addressed. The grid compliance analyses for the large-scale OWPP integration are carried out by using the grid connection criteria defined in the Turkish grid code. PV and QV curves are obtained to assess the effect of OWPP on the static voltage stability limit. Eight scenarios are conducted to analyze the effect of the OWPP on the static and dynamic characteristics of the power grid. To observe the large-scale OWPP impact on the voltage and frequency stability, transient events such as the outage of conventional power plants and three-phase to ground faults are applied. The results of the voltage and frequency stability analysis reveal that the Turkish grid remains stable after the integration of an 1800 MW OWPP. Furthermore, the Turkish system remains stable even in the event of an outage of the international transmission lines to Bulgaria and Greece. |
tr_TR |
dc.language.iso |
en |
tr_TR |
dc.publisher |
IEEE ACCESS / IEEE-INST ELECTRICAL ELECTRONICS ENGINEERS INC |
tr_TR |
dc.relation.ispartofseries |
2022;Volume: 10 |
|
dc.subject |
Power system stability |
tr_TR |
dc.subject |
Power grids |
tr_TR |
dc.subject |
Circuit stability |
tr_TR |
dc.subject |
Voltage |
tr_TR |
dc.subject |
Renewable energy sources |
tr_TR |
dc.subject |
Power system dynamics |
tr_TR |
dc.subject |
Wind power generation |
tr_TR |
dc.subject |
Grid code |
tr_TR |
dc.subject |
grid integration |
tr_TR |
dc.subject |
offshore wind power plants |
tr_TR |
dc.subject |
voltage |
tr_TR |
dc.subject |
frequency stability |
tr_TR |
dc.title |
Impacts of Large-Scale Offshore Wind Power Plants Integration on Turkish Power System |
tr_TR |
dc.type |
Article |
tr_TR |