DSpace Repository

Isolated H-bridge DC-DC converter integrated transformerless DVR for power quality improvement

Show simple item record

dc.contributor.author Savrun, Murat Mustafa
dc.contributor.author Koroglu, Tahsin
dc.contributor.author Tan, Adnan
dc.contributor.author Cuma, Mehmet Ugras
dc.contributor.author Bayindir, Kamil Cagatay
dc.contributor.author Tumay, Mehmet
dc.date.accessioned 2023-01-16T13:06:53Z
dc.date.available 2023-01-16T13:06:53Z
dc.date.issued 2020-04
dc.identifier.citation Savrun, M. M., Köroğlu, T., Tan, A., Cuma, M. U., Bayindir, K. Ç., & Tümay, M. (2020). Isolated H‐bridge DC–DC converter integrated transformerless DVR for power quality improvement. IET Power Electronics, 13(5), 920-926. https://doi.org/10.1049/iet-pel.2019.0687 tr_TR
dc.identifier.issn 1755-4535
dc.identifier.issn 1755-4543
dc.identifier.uri http://openacccess.atu.edu.tr:8080/xmlui/handle/123456789/4134
dc.identifier.uri http://dx.doi.org/10.1049/iet-pel.2019.0687
dc.description WOS indeksli yayınlar koleksiyonu. / WOS indexed publications collection. tr_TR
dc.description.abstract This study presents a new H-bridge DC-DC converter-based transformerless dynamic voltage restorer topology (DVR). The proposed system can compensate balanced and unbalanced voltage sag/swell that are the most common electrical power quality problems and offers advantages over conventional DVR topologies by providing the isolation with high-frequency transformer (HFT) rather than bulky injection transformers and by employing shunt converter to eliminate the requirement of an energy storage unit. The system is composed of H-bridge DC-DC converter equipped with a HFT with one primary and three secondary windings and transformerless DVR. The single-phase shift modulation method is used for each series converter independently to provide the bidirectional power flow control of DC-DC converter, whereas in-phase compensation method with a hybrid detection algorithm is used to mitigate voltage sag/swell. An LC filter is employed to attenuate the switching ripple harmonics on the output of the DVR. The performance of the proposed system is verified experimentally on a three-phase, three-wire, 380 V, 10 kVA prototype. tr_TR
dc.language.iso en tr_TR
dc.publisher IET POWER ELECTRONICS / INSTITUTION ENGINEERING TECHNOLOGY-IET tr_TR
dc.relation.ispartofseries 2020;Volume: 13 Issue: 5
dc.subject DYNAMIC VOLTAGE RESTORER tr_TR
dc.subject INVERTER tr_TR
dc.subject COMPENSATION tr_TR
dc.subject TOPOLOGIES tr_TR
dc.subject FILTER tr_TR
dc.subject SAG tr_TR
dc.title Isolated H-bridge DC-DC converter integrated transformerless DVR for power quality improvement tr_TR
dc.type Article tr_TR


Files in this item

Files Size Format View

There are no files associated with this item.

This item appears in the following Collection(s)

Show simple item record

Search DSpace


Advanced Search

Browse

My Account