In this study, energy and exergy analyses are performed for an Organic Rankine Cycle in a local power plant that is located southern of Turkey. The Organic Rankine Cycle was used for low temperature heat source asheat recovery process with various organic working fluids. The examined system consists of an evaporator, a turbine, a condenser, a pump and a generator as components. The evaluation is carried out using two different working fluidsfor each component of the system. The main purpose of this study is to model the ORC cycle for performance optimization in terms of the usage of two different working fluids with relevant temperature ranges. HFE7100 and FC72 working fluids are selected as performance parameters in order to show the effect of the working fluids on the system performance of the Organic Rankine Cycle.
Bu çalışmada, Türkiye'nin güneyinde bulunan bir yerel güç santralindeki Organik Rankine Çevrimi için ekserji analizi yapılmıştır. Organik Rankine Çevrimi, düşük sıcaklıktaki ısı kaynağı için farklı organik soğutucu akışkanlar ile ısı geri kazanım işlemi olarak kullanılır. İncelenen sistem evaporatör, türbin, kondenser, pompa ve jeneratör bölümlerinden oluşmaktadır. Değerlendirme, her sistem bileşenine iki farklı soğutucu akışkan için yapılmıştır. Bu çalışmanın temel amacı,Organik Rankine Çevriminin performans optimizasyonunu sağlamak üzere iki farklı soğutucu akışkanınilgili sıcaklık aralıklarında kullanılarak modellenmesidir. Soğutucu akışkanların Organik Rankine Çevriminin performansı üzerine etkisini göstermek amacıyla HFE7100 ve FC72 akışkanları performans parametresi olarak seçilmiştir.