dc.contributor.author |
Aydin, Rozelin |
|
dc.contributor.author |
Atakav, Yagmur |
|
dc.date.accessioned |
2020-03-19T12:50:54Z |
|
dc.date.available |
2020-03-19T12:50:54Z |
|
dc.date.issued |
2018 |
|
dc.identifier.citation |
AYDIN, R , ATAKAV, Y . (2018). Adana İli Seyhan İlçesindeki Su Depolarının Bakteriyolojik ve Fizikokimyasal Açıdan İncelenmesi. Çukurova Üniversitesi Mühendislik-Mimarlık Fakültesi Dergisi , 33 (1) , 131-142 . DOI: 10.21605/cukurovaummfd.420689 |
tr_TR |
dc.identifier.issn |
1019-1011 |
|
dc.identifier.issn |
2564-7520 |
|
dc.identifier.uri |
http://openaccess.adanabtu.edu.tr:8080/xmlui/handle/123456789/801 |
|
dc.identifier.uri |
https://doi.org/10.21605/cukurovaummfd.420689 |
|
dc.description |
TR Dizin indeksli yayınlar koleksiyonu. / TR Dizin indexed publications collection. |
tr_TR |
dc.description.abstract |
Bu çalışma, Adana’nın Seyhan ilçesindeki apartmanlardaki su depolarının fizikokimyasal vemikrobiyolojik kalitesinin belirlenmesi amacıyla yapılmıştır. Bu amaç doğrultusunda 53 apartmandandepo giriş, depo çıkış ve 1. kat olmak üzere toplamda 159 adet su numunesi toplandı. Su numunelerindefizikokimyasal özelliklerden tat, koku, bulanıklılık, toplam sertlik, pH ve bakiye klor ölçümü yapılırken,mikrobiyolojik olarak 37 C’de koloni sayımı, Enterekok, E. coli, total koliform bakterilerin varlığıaraştırıldı. Depo girişinden, yani şebekeden alınmış olan su örneklerinde %0,63 oranında total kolonisayımında, %1,89 oranında ise total koliform bakteri, %0 E. coli uygunsuzluğuna rastlanmıştır. Çıkışsularında ise %0,63 enterekok, %14,5 total koloni sayımı, %5 total koliform ve %0 E. coli bakteri tespitedilmiştir. Saha da yapılan ölçümlerde bakiye klor sadece 4 apartmanın su deposunda ölçülebilmiştir. Sunumunelerinin geneli orta sertlikte olduğu gözlemlenmiştir. Alınan su numunelerinde 2 istisnai örnekdışında renk, tat, bulanıklılık ve koku problemi de bulunmamaktadır. Örneklerin pH düzeyleriincelendiğinde şebeke suyunun 6,9-8,4 değerleri arasında ve ortalama 7,4 değerinde olduğu ölçülmüştür.Yapılan çalışma sonunda, suyun bina içi su yapılarına kadar temiz bir şekilde ulaştığı varsayılsa bilesuların depolandığı su depolarının çok kritik bir öneme sahip olduğu görülmüştür. |
tr_TR |
dc.description.abstract |
This study was carried out in order to determine the physicochemical and microbiological quality of thewater storage tanks located in the apartment buildings in the Seyhan district of Adana. For this purpose, atotal of 159 water samples were collected from 53 apartment, including the inlet, outlet of water storagetank and from the first floor. Colonic counts at 37 C, Enterecocci, E. coli, total coliform bacteria wereinvestigated for microbiological analysis, while taste, odor, turbidity, total hardness, pH and residualchlorine were measured for physicochemical properties in water samples. The samples that were taken from the inlet of the tanks showed 0,63% total coliform bacteria, 1,89% total colonic counts, 0% E. coli.The outlet sample analysis indicated 0,63% Enterecocci, 14,5% total colonic counts, 5% total coliformbacteria and 0% E.coli. In the field measurements, the residual chlorine was only measured for 4apartments. It had been observed that the water samples were of the medium moderate hardness. Also, nocolor, taste, turbidity or odor problems were observed in the samples except for 2 water samples. Whenthe pH levels of the samples were examined, it was measured that the pH of the tap water had valuesvarying between 6.9-8.4 and an average value of 7.4. As a result of our study, it was seen that even if thewater reaches in a clean condition up to the in-building water structures, the tanks that the water is keptplay an important role in the sanitation of the water. |
|
dc.language.iso |
other |
tr_TR |
dc.publisher |
Çukurova Üniversitesi Mühendislik-Mimarlik Fakültesi Dergisi / Çukurova Üniversitesi |
tr_TR |
dc.relation.ispartofseries |
2018;Volume: 33 Issue: 1 |
|
dc.subject |
Fen |
tr_TR |
dc.subject |
Mühendislik |
tr_TR |
dc.subject |
Mimarlık |
tr_TR |
dc.subject |
Su depoları |
tr_TR |
dc.subject |
bakteriyolojik ve fizikokimyasal kirlilik |
tr_TR |
dc.subject |
Enterekok |
tr_TR |
dc.subject |
E. coli |
tr_TR |
dc.subject |
total koliform |
tr_TR |
dc.subject |
Water storage tanks |
tr_TR |
dc.subject |
bacteriological and physicochemical pollution |
tr_TR |
dc.subject |
enterecocci |
tr_TR |
dc.subject |
total coliform |
tr_TR |
dc.title |
Adana İli Seyhan İlçesindeki Su Depolarının Bakteriyolojik ve Fizikokimyasal Açıdan İncelenmesi |
tr_TR |
dc.title.alternative |
Bacteriological and Physicochemical Investigation of Residential Water Storage Tanks in the District of Seyhan, Adana Province |
tr_TR |
dc.type |
Article |
tr_TR |